Commercial and industrial

Solar and storage for business, engineered from start to finish.

Shops, offices, schools, hospitals and factories use most of their power in the day, exactly when panels produce it. We engineer, source and build systems from 10 kW for a shop to several hundred kilowatts for a factory, with battery storage where it pays.

Workers in orange uniforms and white helmets install solar panels across a huge factory roof, with hills behind
Why daytime use matters

Almost every unit your panels make is used on the spot.

Under net billing a unit sent to the grid earns far less than a unit you use yourself saves. A home is often empty in the day; your business is not. That is why businesses and schools often see their system pay for itself in about 2 and a half to 4 years.

A unit you use yourself saves

about Rs 55

A unit you send to the grid earns

about Rs 8

Typical 2026 figures. Tariffs and the NEPRA export rate change; our calculator always uses the current ones.
Rows of solar panels on a flat commercial roof on either side of a yellow maintenance walkway, in warm sunlight
Shops, offices and clinics

Keep the ACs, fridges and computers running for less.

Most shops and offices need 10 to 30 kW. A hybrid inverter can keep your tills, computers and medicine fridges on through load shedding, with a battery sized to the essentials only.

  • Sized to your opening hours and your last 12 bills
  • Backup for the equipment that must not stop
  • Installed after hours or on a Sunday if you need
Rows of blue solar panels on a flat rooftop under a bright blue sky, with domed brick buildings behind
Schools, hospitals, mosques and NGOs

Big flat roofs and daytime use: the best case for solar.

Larger schools and hospitals usually need 50 to 200 kW. We plan the work around term dates and patients, split big systems into sections that can be serviced one at a time, and give you a monitoring screen for the office.

  • Work planned around holidays and opening hours
  • Backup for operating theatres, labs or server rooms where needed
  • A clear report for your board or trustees

See our school and hospital projects

Aerial view of a large factory complex with solar panels covering several flat roofs
Factories and warehouses

Three-phase systems from 100 kW, built around your shifts.

Factories usually need 100 kW or more, on a three-phase connection. We study your load profile and your industrial tariff, fix panels to steel roofs without drilling through the sheet, and leave walkways for cleaning. For large sites we give a range first and the exact design after a full site survey.

  • Designed around day and night shifts
  • Clamp rails for steel roofs, walkways for cleaning
  • Surge protection and monitoring on every inverter

See our factory projects

Battery storage (BESS) for peak hours and outages

How we run a project

Engineering, procurement and construction, under one roof.

One team answers for the whole job, from the first site survey to the monitoring screen in your office.

120+

commercial and industrial clients

26years

of engineering solar systems

Panel and inverter brands we install

  1. Site survey and load study

    Your roof and structure, your main panel, your maximum demand and your last 12 bills, so the design fits how you really use power.

  2. Engineering and design

    Layout, structure, cable sizes and protection, a single-line diagram, and a yield and payback worked out on your own tariff.

  3. Sanctioned load, DISCO and NEPRA

    A grid-connected system cannot be bigger than your sanctioned load; if you need more, we apply to raise it. Up to 25 kW your DISCO approves the system. Above 25 kW NEPRA must approve it too, and from 250 kW a load-flow study is needed.

  4. Procurement

    Panels, inverters, structures and protection from brands we know, delivered in stages so your site is never cluttered.

  5. Construction and commissioning

    Safe work at height, clean cable runs, every protection tested, the net billing agreement and green meter, then training for your staff.

  6. Operation and maintenance

    Monitoring you can check from your phone, a cleaning plan for your dust level, and a report on how the plant is performing.

Questions

What businesses ask us.

See all questions

Why does solar pay back faster for businesses and schools?

Offices, shops, schools, clinics and factories use most of their electricity in the day, while the sun is up. Almost every unit the panels make is used straight away and saves the full price of a unit, instead of being sold to the grid at a low rate.

What size of system does a business need?

Small shops and clinics usually need 10 to 30 kW. Larger schools and hospitals need 50 to 200 kW, and factories 100 kW or more.

The right size depends on your daytime use, your sanctioned load and your roof. For anything above about 25 kW we visit the site, study your last 12 bills and design the system with you.

Do larger systems need NEPRA approval?

Yes. Systems up to 25 kW are approved by your DISCO. Above 25 kW, NEPRA's approval and a one-time fee for each kW are also needed, and systems of 250 kW or more need a load-flow study of the grid nearby. We prepare and file all of it.

Book a free site survey.

Send us your last few bills on WhatsApp. We will come to see the site and give you a written proposal with the payback worked out.

Associated partners

Panels, inverters and batteries from the brands we work with.

See products and brands